Reflex is Synaptec’s range of ultrafast power system protection for complex and remote circuits and assets.

Reflex identifies the faulted zone in milliseconds, using passive optical sensors with no power, active electronics, or communications at the measurement sites. The range includes MCP for mixed overhead and cable circuits and RTP for remote transformers.

Both run on Distributed Electrical Sensing (DES): passive sensors on standard current transformers, read over a spare fibre by a DES Interrogator in the substation.

Get in touch

Aneesh Chandran

Aneesh Chandran

Sales Engineering lead

Prasanta Das

Prasanta Das

Regional Sales Director - India & Gulf States

Dr Oyedotun E. Oyewole

Dr Oyedotun E. Oyewole

Sales Engineer

Protection for remote circuits and assets

Unit protection needs a current measurement at each end of the protected zone. Inside a substation that is routine. At a cable sealing end on a transition tower, a transformer on a remote tap, or a cable landing point, there is usually no auxiliary supply, no communications link fit for protection, and no time source. Building them costs more than the asset often justifies, so many of these sites are left with slower and less selective protection than the asset deserves.

Reflex keeps every active device in the substation. Passive Secondary Converters (PSCs) on the secondary of standard current transformers encode the current as light on a spare fibre back to a DES Interrogator. The Interrogator reads every sensor on one time base, runs differential protection across the zones you define, blocks or permits auto-reclose, and passes Sampled Values to your own relays. Nothing at the remote site needs power, maintenance, or recalibration.

Synaptec passive sensors mounted on a 110 kV transition tower in Romania

Passive sensors on a 110 kV transition tower in Romania

The Reflex range

Mixed circuit protection (MCP)

MCP tells the protection scheme whether a fault on a mixed circuit is in a cable section or on the overhead line, and blocks auto-reclose for cable faults before the breaker opens. Overhead faults reclose as normal.

MCP protection zones: passive sensors on split-core CTs below the sealing end at each transition tower and on the substation CT form a zone around every cable section, connected by one spare fibre to the DES Interrogator, which sends an auto-reclose block to the Main 1 and Main 2 relays

Remote transformer protection (RTP)

RTP gives unit protection to a transformer far from any substation. The HV line, the transformer, and the LV line each have their own zone, measured from the substation, with the transformer zone run by your choice of 87T relay.

RTP protection zones: the DES Interrogator runs line differential on the HV and LV line zones and permits auto-reclose for line faults; the transformer zone runs in the operator's chosen 87T relay from Sampled Values and blocks auto-reclose for transformer faults; main and backup relays are unchanged

Key benefits

  • Unit protection with no substation at the far end. Reflex applies differential protection across cable sections, lines, and transformers whose ends have no relay, power supply, or communications.
  • Faulted zone identified in under 10 ms. Mixed circuit schemes in service identify the faulted zone and issue the auto-reclose block in under 10 ms, before the breaker opens.
  • More than 60 km from the substation. One DES Interrogator reads sensors along a single fibre, in series or in parallel, to more than 60 km from the substation.
  • Nothing to maintain at the remote site. The sensors need no power, batteries, data network, or time source, and are designed for more than 30 years in service without recalibration.
  • Works with the relays you have. Dry contacts, IEC 61850 GOOSE, and IEC 61850-9-2 Sampled Values connect Reflex to conventional and digital substations alike.
  • Standard current transformers. The sensors connect to any industry-standard CT with a 1 A or 5 A secondary, existing or new, including split-core CTs fitted around cables already in service.
  • Nothing to attack at the remote site. Only optical signals leave the substation fence. There are no IP addresses, radios, or active electronics at the measurement sites.
Synaptec DES Interrogator, 3U rack-mounted

DES Interrogator, 3U rack-mounted

Proven in service

MCP and RTP use the same DES Interrogators and passive sensors that Synaptec supplies for protection and cable systems monitoring worldwide. In more than 1.5 million sensor-hours of operation, no Synaptec sensor has ever failed in service.

>1.5 million

sensor-hours of operation (October 2026)

<10 ms

to identify a faulted zone on mixed circuits in service

>60 km

from the substation to the furthest passive sensor

In service and in delivery

MCP is in service and in delivery with transmission and distribution operators in India, Europe, and the Middle East, and Synaptec has developed unit protection for multi-ended circuits and busbars with network operators in the UK and Norway.

See the MCP references

Monitoring on the same fibre

The passive sensors and DES Interrogators used in MCP and RTP also carry Greenlight®, Synaptec’s cable systems monitoring, which measures current and temperature at joints and terminations and gives early warning of developing faults.

How Reflex is delivered

Design

Synaptec reviews your single-line diagram and fibre route and proposes a protection design with a budget price, at no cost.

Supply

Synaptec supplies the passive sensors, the DES Interrogator, and the software, and supports your relay integration.

Installation

Your preferred contractor or Synaptec’s local partner fits the CTs and sensors and splices them into the spare fibre.

Commissioning and support

Synaptec commissions the scheme from the substation, with no test sets at the remote site, and provides support with local first-line cover where a partner is in place.

Reflex brochure

The Reflex brochure covers MCP and RTP, how each one works, and the service record of the Synaptec passive sensors and DES Interrogators they share, in eight pages.

Talk to us about your circuits and assets

Start with one circuit. Send us the single-line diagram and the fibre route, and we will propose a protection design with a budget price, at no cost. Your preferred contractor or Synaptec’s local partner installs the equipment, and Synaptec commissions it.

Country(Required)
Read our data privacy policy here. By registering above, you are opting in to our newsletter and communications.
This field is for validation purposes and should be left unchanged.

Related posts

Mixed Circuit Protection (MCP)

Mixed Circuit Protection (MCP)

Mixed Circuit Protection (MCP) is Synaptec’s solution to eliminate the risk of auto-reclosing on a permanent cable fault. MCP utilises Synaptec’s platform technology, Distributed Electrical Sensing (DES), to instantly detect whether a fault has occurred on a cable...

read more
Distributed Electrical Sensing (DES)

Distributed Electrical Sensing (DES)

We reduce outage and operational cost with the world’s only distributed sensor technology for operators of complex power systems. Our passive sensors require no power or data networks, and provide live data more reliably and securely from more locations than...

read more

Sectors we support

Power grids

Renewables

Industrial